Selja einingar | : | Set/Sets |
Notaðu umhverfi
Umhverfishitastig -20 ~ +55 ℃
Hlutfallslegt hitastig 5% ~ 95%Andrúmsloftsþrýstingur 86-106kPa
Sprengingarþétt gerð -20 ~ 70 ℃
Tengingaruppbygging og stærð:
Snittari smíði
Stilling breytu
Main Menu |
Cipher |
Option |
Set value |
Instruction |
Parameter
setting |
10000 |
Language |
Chinese/English |
1. Preset selection 2. Default Chinese |
Mailing address |
0~254 |
1. Enter the device,communication address 2. This option is not available for battery power 3. Select current output product, this setting is invalid 4. Only selected communication products with 485 take effect 5. Default address 001 |
||
Baud rate |
2400、4800、9600、19200 |
1. 1. Preset selection,Baud rate of device communication 2. This option is not available on battery power 3. Select current output product, this setting is invalid 4. Only the communication product with 485 takes effect 5. Default 2400 |
||
Flow unit |
m3/h, m3/m, m3/s, L/h, L/m, L/s, Kg/h, Kg/m, Kg/s |
1. Preset selection 2. The default is m3/h |
||
Range setting |
0~59999 |
1. Input setting 2. Range units change as flow units are modified 3. The default value is 100 |
||
Damping time |
1~16 |
1. Enter the Settings 2. The default value is 04 |
||
Small signal excision |
0~100% |
1. Input setting 2. If the input is greater than 100%, it is equal to 100% 3. Default 0 |
||
Instrument coefficient |
1~9999999 |
1. Input setting 2. Correct the flow value 3. Default 3600 |
||
Set density |
1~59999 |
1. Input setting 2. Modified fluid density 3. Default 1000Kg/ m3 |
||
Output mode |
Pulse output/current output |
1. Preset selection 2. Battery powered does not have this option 3. Select the product with 485 communication function, this setting function is invalid if set to current output, only pulse output can be selected 4. Default current output |
||
Cumulative setting |
0~999999999.999 |
1. Input setting 2. The default value is the actual total value of the system |
||
Current zero correction |
0~5.9999 |
1. Input setting 2. The default value is the factory revision value. Users are prohibited to modify it under special circumstances |
||
Current full degree correction |
0~5.9999 |
1. Input setting 2. The default value is the factory revision value. Users are prohibited to modify it under special circumstances |
Fyrirtækið okkar hverflisrennslismælir er mest seldi rennslismælir, við framleiðum einnig kalt eða hitastreymi, stigmælingu eða hljóðfæri og aðra vinsæla metra, ef þú þarft, vinsamlegast ekki hika við að hafa samband við okkur.
Persónuverndaryfirlýsing: Persónuvernd þín er mjög mikilvæg fyrir okkur. Fyrirtækið okkar lofar ekki að birta persónulegar upplýsingar þínar til allra útgjalda með skýrum heimildum þínum.
Fylltu út frekari upplýsingar svo það geti haft samband við þig hraðar
Persónuverndaryfirlýsing: Persónuvernd þín er mjög mikilvæg fyrir okkur. Fyrirtækið okkar lofar ekki að birta persónulegar upplýsingar þínar til allra útgjalda með skýrum heimildum þínum.